Disposable columns, 10~30ml, 2sets/pk
»óÇ°°¡ 0¿ø(ºÎ°¡¼¼Æ÷ÇÔ)
±¸¸Å¼ö·®

°³
Á¦Á¶»ç BEAMSBIO
¿ø»êÁö Çѱ¹
»óÇ°ÄÚµå DSC-301S
»óÇ°¿É¼Ç



* »çÀºÇ° : ÁÖ»ç±â ÇϺÎ(¹Ù´Ã²ÈÀÌ) ¸¶°³¿Í ¼ö¾×Á¦¼¼Æ®¿ë 3-way valve¸¦ Ä÷³´ç 1°³¾¿ Á¦°øÇÕ´Ï´Ù. ¾Æ·¡ ±×¸²¿¡ ÀÖ´Â ¹ëºê¿Í ´Ù¸¨´Ï´Ù.

1. Name : Disposable column 10~30ml (Catalog# DSC-301S)
               10~30ml ÀÏȸ¿ëÄ÷³/ÁÖ»ç±â¿ë Å°Æ®

2. Spec. :  Column volume varies from 10ml to 30ml

3. Materials : Column Tube & Adaptor/PP, Filter/STS316L,
                    O-ring/VITON, Line & Valve/PTFE

4. Packing :  2 sets/pk, 
   consisted of
      - 2sets, empty columns of 10~30ml CV with adaptor
      - 2ea.,  M6 male unions with 1/16" female
      - 1ea.,  30ml disposable syringe

5. Option : ÆßÇÁ¿ë Å°Æ®
      - 2ea., 1/16" male unions with M6 female
      - 2sets, PTFE tubing set (2.1¥Õ x 1m with union connectors)

ÀÏȸ¿ë Ä÷³ »ç¿ë¹ý : (5ml, 10ml, 30ml °øÅë)

1. ·¹Áø ÃæÁø

1 ·¹ÁøÀº 50~75% ½½·¯¸®·Î ÅõÀÔÇ쵂 20% EtOH ¶Ç´Â Áõ·ù¼ö »ç¿ëÀ» ÃßõÇÔ.

2 Ä÷³ÇϺθ¦ ¹ëºê ¶Ç´Â ¸¶°³·Î ¸·°í ·¹ÁøÀ» ÃæÁøÇÏ°í Ä÷³¾Æ´äŸ¸¦ ÀåÂøÇÔ.

2. ÆßÇÁ¿¡ ¿¬°á : ±×¸² (A) ÂüÁ¶

Æ©ºù¿¬°á±¸¸¦ ÆßÇÁ¿¡ ¿¬°áÇÏ¿© ¹öÆÛ¸¦ ä¿î´ÙÀ½ ¾Æ´äŸ »óºÎ ¿¬°á±¸¿¡ ±âÆ÷°¡ µé¾î°¡Áö ¾Ê°Ô ¿¬°áÇÔ. ÆßÇÁ¿¬°á¹æ½ÄÀº »óȲ¿¡ µû¶ó ´Ù¸£¹Ç·Î ÇÊ¿ä ½Ã, ÇÍÆÃÀ» »ç¿ëÇϰųª Æ©ºùÀ» Àß¶ó¼­ ¿¬°áÇϰųª ÀûÀýÇÑ ¹æ¹ýÀ¸·Î ÇØ°áÇÔ(µµ¿òÀº ¹®ÀÇ¿ä¸Á!)

3. Gravity ÀÌ¿ë : ±×¸² (B) ÂüÁ¶

Ä÷³¾Æ´äŸ ¿¬°á±¸¿¡ ¹öÆÛ¸¦ ¼Ò·® ä¿î ÀÏȸ¿ë ÁÖ»ç±â(¿ë·®Àº ¹öÆÛ ÅõÀÔ·®¿¡ µû¶ó ¼±Á¤)¸¦ ¿¬°áÇÏ°í Èê·Áº¸³¾ ¹öÆÛ¿Í »ùÇÃÀ» Â÷·Ê·Î ÅõÀÔÇÏ¿© »ç¿ëÇÔ.
-------------------------------------------------------
BPXTM Disposable Column, 10~30ml : Cat.#DSC-301S for 2sets

BPXTM Disposable column are family of BPX series columns targeted for rapid and convenient chromatographic works.  The life time of BPX dispoable column may be extended over years depending upon the experimental conditions.

¡¤            Column Tube : the same as disposable syringe

¡¤            Adaptor : Variable position. O-ring is used for sealing reliably the column.

¡¤            Filter : Stainless Steel 316L sintered wire mesh filter & 10§­  of filter opening used

¡¤            Connector :  1/16¡± male and M6 female, compatible to industrial standards

¡¤            Linear velocity :  > 600cm/hr

¡¤            pH stability :      2~14

¡¤            Pressure & Temp.:  upto 1.5bar & upto 40¡É


Column Data

Type

ID

(mm)

Area

(cm2)

Length

(cm)

Vol. (ml)

Dimension

OD¥Õ x H(mm)

Disposable column, 5ml

12

1.13

4.5

5ml, fixed

14¥Õx85

Disposable column, 10ml

15

1.77

5.7

10ml, fixed

17¥Õx102

Disposable column, 5~10ml

15

1.77

5.7

5~10ml, variable

17¥Õx102

Disposable column, 10~30ml

22

3.80

25

10~30ml, variable

24¥Õx133








 
             (ÁÖ)ºö½º¹ÙÀÌ¿À 13210 °æ±âµµ ¼º³²½Ã Áß¿ø±¸ »ç±â¸·°ñ·Î 52 (¼±ÅýÃƼ2) B104È£ ÀüÈ­:031-737-4970 Æѽº:031-737-4972